The door that connects any room to an exit route must swing out in the direction of exit travel if the room is designed to be occupied by more than 50 people or if the room is a high hazard area i e contains contents that are likely to burn with extreme rapidity or explode.
Osha door landing requirements.
1910 25 b 3 stairs have uniform riser heights and tread depths between landings.
Stairways that will not be a permanent part of the structure on which construction work is being performed shall have landings of not less than 30 inches 76 cm in the direction of travel and extend at least 22 inches 56 cm in width at every 12 feet 3 7 m or less of vertical rise.
Also in such locations it is permissible when screen doors or other doors are installed especially on the same jamb as the exit door to swing them over stairs steps or landings.
Step from the threshold down to the landing on both sides of the door.
Spiral stairs must meet the vertical clearance requirements in paragraph d 3 of this section.
09 10 2002 1910 36 b minimum width of exit routes.
The door that connects any room to an exit route must swing out in the direction of exit travel if the room is designed to be occupied by more than 50 people or if the room is a high hazard area i e contains contents that are likely to burn with extreme rapidity or explode.
1917 120 b 3 fixed stairs having four or more risers shall have stair railings or handrails complying with 1917 112 c 1.
1910 36 there are no specific osha standards or requirements applicable to overhead doors.
Application this section covers all stairways including standard spiral ship and alternating tread type stairs except for articulated stairs stairs that change pitch due to change in height at the point of attachment such as those serving floating roof tanks stairs on scaffolds stairs designed into machines or equipment and stairs on self propelled motorized equipment.
The general requirement for the specified egress door is a maximum 11 2 in.
Minimum number at least 60 of public entrances must be accessible in new construction in addition to entrances directly serving tenancies parking facilities pedestrian tunnels and elevated walkways.
Door swing shall not reduce effective standing area on the landing to less than 18 inches 45 72 cm in depth.
Landing requirements for egress exterior doors.
The revision in the 1988 ubc which limited the door to opening on an interior stair and excluded exterior stairways was an important change that is often overlooked.